Pipeline Processing

Pipeline Activation

ECLAIRs pipeline of the QLA Process shall be initiated in automatic way as soon as a given set of preliminary input data are made available by the PP pipeline of the QLA process. The amount and criteria of the set of data to be collected before activation is TBD. However the processing and analysis shall provide results within a typical timescale of 1 day.

ECLAIRs pipeline of the SA Process shall be initiated when all consolidated input data of a given observation (obsID) are made available by the PP of the SA process.

Prerequisites

All the predefined input data set along with the required parameters for the specified (QLA or SA) run shall be available before starting the activation of the pipeline.

Input and Output Data

Table 2 lists the input data for each component of the ECLAIRs pipeline and the pipeline or component from which they are generated. Meaning of input data acronyms are fully explained in AD5 for the data products (see also output of PP processing, sect. 5, Tab. 5.1) and in Table 3 of input auxiliary data. Brackets indicate optional input/output. An asterisks indicate that the information may be transmitted in the input files derived from previous components (e.g. in the fits headers) rather than by the direct reading of the specified data products.

Table Input and Auxiliary Data ECPI

Input and Auxiliary Data ECPI A VOIR

PIPELINE COMPONENT

INPUT and Auxiliary Data and SDP

From

OUTPUT SDP (primary in bold)

Format

Data Preparation and Correction (DPCO)

SVO-OBP

(PP)

ECL-GTI-1

FITS-T

SVO-HKS

PP

ECL-PIX-LIV

FITS-T

SVO-ATT-CNV

PP

ECL-EVT-COR

FITS-T

SVO-ORB-CNV

PP

ECL-HKS

PP

ECL-EVT-CNV

PP

ECL-DET-CNV

PP

AUX-ECL-INP-CNF

EIC

AUX-ECL-HKP-LIM

EIC

AUX-ECL-PIX-STA, THR

EIC

AUX-ECL-DPI-DTI

EIC

Calibration (CALI)

ECL-GTI-1

DPCO

ECL-GTI-2

FITS-T

ECL-PIX-LIF

DPCO

ECL-EVT-CAL

FITS-T

ECL-EVT-COR

DPCO

AUX-ECL-PIX-CAL

EIC

(Selection) Binning, Uniformity, Background and Earth Correction (BUBE)

SVO-OBP *

(PP)

ECL-GTI-3

FITS-T

SVO-ATT-CNV *

PP

ECL-DET-IMA

FITS-I

SVO-ORB-CNV *

PP

ECL-DET-UBC

FITS-I

ECL-GTI-2

DPCO

ECL-PIX-LIF

DPCO

ECL-EVT-CAL

CALI

AUX-ECL-INP-CNF

EIC/FSC

AUX-ECL-DET-UNI

EIC

AUX-ECL-ORB-SAA

EIC

AUX-ECL-BKG

EIC/FSC

AUX-ECL-EAR-ALB

EIC/FSC

AUX-ECL-EAR-MOD

FSC/EIC

AUX-GPS-ECL-CAT

FSC

Imaging Source Detection (IMAG)

SVO-OBS-CNV *

PP

ECL-SKY-IMA

FITS-I

SVO-ATT-CNV *

PP

ECL-SOP-IMA

FITS-T

ECL-DET-UBC

BUBE

ECL-DET-MOD

FITS-I

AUX-ECL-INP-CNF

EIC/FSC

AUX-ECL-RSP-VIG

FSC/EIC

AUX-ECL-RSP-ATT

FSC/EIC

AUX-ECL-RSP-ENE

EIC

AUX-GPS-ECL-CAT

FSC

Source Product Extraction (SOEX)

SVO-OBS *

PP

ECL-EVS-Sii

FITS-T

SVO-ATT-CNV *

PP

ECL-LCS-Sii

FITS-T

SVO-ORB-CNV

PP

ECL-SPS-Sii

FITS-T

ECL-EVT-CAL

CALI

(ii = 0, n_sources)

ECL-GTI-3

BUBE

ECL-DET-UBC

BUBE

(ECL-SOP-IMA)

(IMAG)

AUX-ECL-INP-CNF

EIC

AUX-ECL-RSP-VIG

EIC

AUX-ECL-RSP-ATT

FSC

AUX-ECL-RSP-ENE

EIC

AUX-GPS-ECL-CAT

FSC

Mosaicking (MOSA)

SVO-OBS *

PP

ECL-SKY-MOS

FITS-I

SVO-ATT-CNV *

PP

ECL-SOP-MOS

FITS-T

SVO-ORB-CNV *

PP

ECL-SKY-IMA

IMAG

ECL-SOP-IMA

IMAG

Interactive SW (ECIS)

All PP and ECPI products and Auxiliary Files

PP ECPI EIC

Report including text and graphic results. Alerts.

pdf asci

A preliminary list of ECLAIRs auxiliary data is reported in Table 3. Final list and data format will be described in detail in the FSC-EIC ICD or in the ECPI pipeline ADD.

Table Input Auxiliary Data

Input Auxiliary Data A VOIR

AUXILIARY DATA

Description

Used by

From

Freq

AUX-ECL-INP-CNF

Instrument Configuration parameters: geometry, mask pattern, materials

All

EIC

Y

AUX-ECL-HKP-CON

Parameters for housekeeping conversion in physical units

PP-ECL

EIC

Y

AUX-ECL-HKP-LIM

Limiting Values for housekeeping (at least two levels: alarm, best science)

DPCO

EIC

Y

AUX-ECL-PIX-STA

ECLAIRs information on the DPIX characteristics: dead, noisy, live pixels, low-energy thresholds

DPCO

EIC

M

AUX-ECL-PIX-THR

ECLAIRs information on the DPIX characteristics: dead, noisy, live pixels, low-energy thresholds

DPCO

EIC

M

AUX-ECL-DPI-DTI

Parameters to compute the dead-time for DPIX

DPCO

EIC

Y

AUX-ECL-PIX-CAL

Calibration parameters for channel-energy conversion: gains and offsets for each pix

CALI

EIC

W

AUX-ECL-DPI-UNI

Uniformity of the DPIX plane

BUBE

EIC

Y

AUX-ECL-ORB-SAA

Limits of SAA for ECLAIRs

BUBE

EIC/FSC

M

AUX-ECL-BKG

Background Model or parameters

BUBE

EIC/FSC

Y

AUX-ECL-EAR-ALB

Earth Albedo data or model parameters

BUBE

EIC/FSC

Y

AUX-ECL-EAR-MOD

Earth Occultation Model parameters

BUBE

FSC/EIC

Y

AUX-ECL-EAR-RFL

Earth Reflection Backg. data or model parameters

BUBE

FSC/EIC

Y

AUX-ECL-RSP-IRF

Off-axis Normalization Sky Image (Vignetting)

IMAG

FSC/EIC

Y

SPEX

MOSA

AUX-ECL-RSP-ENE

ECLAIRS Energy Response including ARF and RMF

IMAG

EIC

Y

SPEX

MOSA

AUX-ECL-RSP-ATT

Attitude roto-translation matrix to correct bias between instrument and platform attitude (thermoplastic deformations).

IMAG

FSC/EIC

Y

SPEX

FSC/EIC

Y

MOSA

AUX-GPS-ECL-CAT

Source Catalogue regularly updated with the ECLAIRs results and possibly with MXT results

BUBE

FSC

D

IMAG

SPEX

MOSA

AUX-ECL-UGT-PAR

Parameters of the UGTS

DPCO

EIC

ECIS

Pipeline input parameters are also needed to run the processes. Those will be specified in the architectural design document of the pipeline.

Table 2 lists also the output science data products (SDP) of each component of the ECLAIRs pipeline. Meaning of SDP acronyms are fully explained in AD5. SDP in bold are primary, the other are secondary as defined in AD5. Detailed description of the ECLAIRs primary SDP is reported elsewhere.